In this case study, ScaleReady helped an autologous T cell therapy company rapidly transition to a closed-system process for cell expansion by providing a testing plan to verify that G-Rex®500M-CS closed-system bioreactors would meet their immediate cell production requirements and improve cell production efficiency, while adhering to their short timelines for going into clinical trials. In doing so, the company also uncovered small changes to their cell culture protocols that made a big impact on their cell production efficiency.

What this paper found

Seeding density, not vessel format, set the ceiling on T cell yield when an autologous T cell therapy company moved its expansion step into closed-system bioreactors. Working with ScaleReady, the company first confirmed that a G-Rex®500M-CS protocol started at a calculated seeding density in cells/cm2 matched the expansion rate and target cell characteristics of its existing open process, clearing the way for pivotal trials. Small-scale G-Rex®6M well plate runs then showed that starting density directly changes fold expansion and final yield, identifying a better density along with a reduced media and cytokine feeding schedule. Because the well plates and the 500M-CS gave similar kinetics and yields per cm2, small-scale screening translated reliably to full manufacturing scale.

Study details

G-Rex® model(s)
G-Rex®500M-CS
Cell type(s)
T-Cells
Study phase
Preclinical

How G-Rex® was used

Clinical-scale expansion was run in G-Rex®500M-CS closed-system bioreactors, seeded at a density calculated by ScaleReady to reach the company's target yield in cells per cm2. Process optimisation was carried out in parallel at small scale in G-Rex®6M well plates, testing seeding density, the maximum achievable cell density, and the minimum cytokine and media feeding schedule. Running both formats showed comparable expansion kinetics and yields per cm2, so G-Rex®6M was adopted as the screening format for reagent comparability and further optimisation before scale-up.

Explore related

Building a similar workflow?

Talk to a ScaleReady specialist about how the G-Rex® platform can support your program — from process development to clinical-scale manufacturing.

Start a conversation →