No compromise in cell expansion: Atract™ Kit T-cell activation reagent performance in closed G-Rex® systems

Overview
This white paper evaluates the Atract T-Cell Activation Kit comparing open and closed workflows. G-Rex® 100M and G-Rex® 100M-CS bioreactors are explicitly referenced for efficient T-cell expansion, demonstrating comparable high cell yields and low exhaustion markers across both setups.
What this paper found
The Atract Kit T-cell activation reagent performed equivalently when the workflow moved from an open to a closed G-Rex® system. PBMCs from three healthy donors were activated and expanded for 9 days in G-Rex® 100M vessels, seeded with 50 × 10^6 cells and 160 mg of Atract Kit. Both setups produced more than 3 × 10^9 cells, with no significant difference between them. Viability stayed above 80%, and the CD4/CD8 ratio was similar, with about 62% CD8 and 38% CD4 cells. Exhaustion markers PD-1, TIM-3 and LAG-3 remained low in the closed system, and CD19-positive cells stayed below 0.5% in both conditions. The closed format used a pre-production prototype of the Atract Kit.
Note: Functional subtype distribution data are not shown in the white paper; the study used three healthy donors.
Final cell counts after the 9-day expansion were comparable between closed and open systems: both protocols achieved >3×10⁹ cells with non-significant differences. — Bio-ReCell, ScaleReady
Study details
- Authors
- Bio-ReCell, ScaleReady
- Institution
- Bio-ReCell d.o.o., Ljubljana-Dobrunje, Slovenia
- Year
- 2026
- G-Rex® model(s)
- G-Rex®100M, G-Rex®100M-CS
- Cell type(s)
- T-Cells
- Application area
- Other
- Study phase
- Preclinical
How G-Rex® was used
Healthy-donor PBMCs (50 × 10^6 cells per vessel) were activated with 160 mg of Atract Kit and expanded in G-Rex® 100M vessels for 9 days in total. The open-system arm used standard G-Rex® 100M vessels with manual seeding, while the closed arm used a closed-system G-Rex® 100M-CS gravity-filled through a tube-welded Atract Kit unit. On day 2, the remaining 95% of medium (950 mL) was added to reach the final volume. At harvest, the closed system used the GatheRex pump to remove about 90% of the medium and transfer cells through a 30 µm filter into a collection bag.
Ecosystem products: ExCellerate · GatheRex
Explore related
Building a similar workflow?
Talk to a ScaleReady specialist about how the G-Rex® platform can support your program — from process development to clinical-scale manufacturing.