A streamlined, end-to-end solution for robust and efficient large-scale CAR T manufacturing

Overview
Miltenyi Biotec evaluates four automated CAR T cell manufacturing workflows. The study compares CliniMACS Prodigy and CliniMACS Plus systems for scalability. A G-Rex® 500M bioreactor is paired with the CliniMACS Plus instrument to support automated cell enrichment and expanded culture capacity.
What this paper found
An automated, closed workflow for CAR T manufacturing produced comparable, high-quality products across scales. Four processes were run in triplicate on three donors: three on the CliniMACS Prodigy and one on the CliniMACS Plus with a G-Rex® 500M. Cells were activated, transduced with a CD19 lentiviral vector at MOI 5 on Day 1, and harvested on Day 7. Viability was 95% to 98%. Yields reached about 3×10⁸ cells in the core process and up to 2×10¹⁰ in the large-scale configuration. Agitated cultures showed stronger activation and higher vector copy numbers. All products were memory-dominated with low exhaustion markers and killed Raji cells, with up to 80–95% lysis at 48 hours.
Note: The G-Rex® 500M workflow was run once per donor alongside three Prodigy workflows; some data (memory phenotype, cytokine release, viability) are described as not shown.
Together, these technologies create a streamlined, end-to-end solution for robust, efficient CAR T manufacturing. — Miltenyi Biotec
Study details
- Authors
- Miltenyi Biotec
- Institution
- Miltenyi Biotec
- Year
- 2026
- G-Rex® model(s)
- G-Rex®500M
- Cell type(s)
- CAR T Cells
- Application area
- Hematologic malignancy
- Study phase
- Preclinical
How G-Rex® was used
A G-Rex® 500M bioreactor was used in workflow D. T cells from the same leukapheresis were enriched on the CliniMACS Plus Instrument, transferred to the G-Rex® 500M, and activated with high-concentration MACS GMP T Cell TransAct at 1×10⁸ cells, as in workflow C. Cells were cultured statically, transduced on Day 1 with a CD19 lentiviral vector at MOI 5, and washed on Day 3. From Day 3 to Day 7 they expanded in TexMACS Medium with IL-7, IL-15 and 3% human AB serum. Workflow D reached among the highest Day 0 to Day 7 fold expansions and was harvested on Day 7.
Note: Pairing the CliniMACS Prodigy with a G-Rex® bioreactor is routinely performed but was not part of this study.
Explore related
Building a similar workflow?
Talk to a ScaleReady specialist about how the G-Rex® platform can support your program — from process development to clinical-scale manufacturing.