All manuscripts
Publications CAR T Cells

An Analysis of Monitoring Solutions for CAR T Cell Production

Published Journal Healthcare Technology Letters

Share
19 pages An Analysis of Monitoring Solutions for CAR T Cell Production

Overview

This review catalogues 47 measurement methods used across CAR T cell production and classifies them by where the measurement is taken. Today only off-line methods give cell count and viability; the authors point to optical and model-based sensors as the route to continuous monitoring.

What this paper found

Most monitoring of CAR T cell manufacturing still depends on off-line or at-line measurements, which are a bottleneck for digital, real-time process control. This literature review of the production steps (selection, activation, gene transfer, expansion and formulation) catalogued 47 measurement methods and sorted them as off-line, at-line, on-line or in-line, together with their data formats and real-time capability. Key parameters were assigned to each step, split into core and research metrics. Cell count and viability can currently be measured only off-line. Optical biosensors and soft sensors, particularly hybrid models, are presented as promising routes toward continuous monitoring, although data standards and regulatory alignment are still lacking.

Note: This is a literature-based review without original experiments; the authors state that the proposed monitoring concept still needs to be implemented and evaluated in concrete applications.

In our view, strict off-line measurement methods are bottlenecks hindering the realization of digital monitoring. — Arber Shoshi, Yuchen Xia, Andrea Fieschi, Yannick Baumgarten, Andrea Gaißler, Thomas Ackermann, Peter Reimann, Bernhard Mitschang, Michael Weyrich, Thomas Bauernhansl, Robert Miehe, Healthcare Technology Letters

Study details

Authors
Arber Shoshi, Yuchen Xia, Andrea Fieschi, Yannick Baumgarten, Andrea Gaißler, Thomas Ackermann, Peter Reimann, Bernhard Mitschang, Michael Weyrich, Thomas Bauernhansl, Robert Miehe
Institution
Graduate School of Excellence advanced Manufacturing Engineering (GSaME), University of Stuttgart, Stuttgart, Germany · Fraunhofer Institute for Manufacturing Engineering and Automation (IPA), Stuttgart, Germany · Institute of Industrial Manufacturing and Management (IFF), University of Stuttgart, Stuttgart, Germany · Institute of Industrial Automation and Software Engineering (IAS), University of Stuttgart, Stuttgart, Germany · Institute for Parallel and Distributed Systems (IPVS), University of Stuttgart, Stuttgart, Germany · Mercedes Benz, Stuttgart, Germany
Journal
Healthcare Technology Letters
Year
2025
PMID / PMC
PMID: 40365510 · PMC
Cell type(s)
CAR T Cells
Application area
Hematologic malignancy

Explore related

Full citation

Shoshi A, Xia Y, Fieschi A, et al. An Analysis of Monitoring Solutions for CAR T Cell Production. Healthc Technol Lett. 2025;12(1):e70012.

Building a similar workflow?

Talk to a ScaleReady specialist about how the G-Rex® platform can support your program — from process development to clinical-scale manufacturing.

Start a conversation →