Silicone rubber membrane devices permit islet culture at high density without adverse effects

Overview
This study demonstrates that G-Rex® devices allow for a 20-fold increase in islet seeding density compared to T-flasks without compromising viability or function. Modeling and experiments confirm that the gas-permeable membrane prevents anoxia in high-density cultures.
What this paper found
Porcine islets cultured for 2 days at high surface density on gas-permeable silicone rubber membrane bases kept their viability and potency, whereas the same density on non-permeable bases destroyed them. Islets from 30 porcine preparations were seeded at up to 4,000 DNA IE/cm², a 20-fold increase over the standard limit of 200 IE/cm² used in T-flask controls. Finite-element models predicted full oxygenation on the membrane but 95.3% anoxic culture volume on non-permeable bases. Across 1,001–4,000 DNA IE/cm², OCR/DNA relative to paired controls averaged 96% on the membrane (n = 24) but 58% without it (n = 13). Diabetes reversal in nude mice receiving 2,000 IE (or its DNA equivalent) was 88% (14/16) after high-density membrane culture, 93% (14/15) for controls and 8% (1/13) after non-permeable high-density culture.
Note: Short-term (2-day) culture of porcine islets, with potency tested in diabetic nude mice. Islet mass was measured by DNA content, which the authors note cannot distinguish islet from non-islet DNA, a minor issue at the 90–95% purity of the preparations used.
Culturing islets in GP devices allows for a 20-fold increase of islet surface area density, greatly simplifying the culture process while maintaining islet viability and metabolism. — Efstathios S. Avgoustiniatos, Kate R. Mueller, William E. Scott III, Jennifer P. Kitzmann, Thomas M. Suszynski, Brian E. Perrault, Eric J. Falde, A. N. Balamurugan, Bernhard J. Hering, Charles W. Putnam, Klearchos K. Papas, Frontiers in Bioengineering and Biotechnology
Study details
- Authors
- Efstathios S. Avgoustiniatos, Kate R. Mueller, William E. Scott III, Jennifer P. Kitzmann, Thomas M. Suszynski, Brian E. Perrault, Eric J. Falde, A. N. Balamurugan, Bernhard J. Hering, Charles W. Putnam, Klearchos K. Papas
- Institution
- Department of Surgery, Schulze Diabetes Institute, University of Minnesota, Minneapolis, MN, United States · Department of Surgery, Institute for Cellular Transplantation, University of Arizona, Tucson, AZ, United States
- Journal
- Frontiers in Bioengineering and Biotechnology
- Year
- 2024
- G-Rex® model(s)
- G-Rex®10, G-Rex®100
- Cell type(s)
- Other
- Application area
- Regenerative medicine
- Study phase
- Preclinical
How G-Rex® was used
In a study of 30 porcine islet preparations, islets were cultured for 2 days in G-Rex®10 and G-Rex®100 devices (Wilson Wolf Manufacturing), whose gas-permeable silicone rubber membrane bases place the islet layer next to ambient oxygen, at surface densities as high as 4,000 DNA IE/cm². The G-Rex®10 has a 10 cm² culture area for research studies of up to 40,000 IE per device, and the G-Rex®100 a 98 cm² area that holds up to 400,000 IE, enough for an entire human or porcine islet preparation; devices with areas of 2.5, 5, 10, 18 and 98 cm² were used. Islets from these high-density cultures were assessed for fractional viability (OCR/DNA) and DNA recovery, and islets from 5 preparations cultured at 1,000 to 3,071 DNA IE/cm² were transplanted into diabetic nude mice.
Note: In the non-permeable high-density comparison, devices with silicone rubber membrane bases were sealed against ambient air with a non-permeable membrane on the bottom.
Explore related
Full citation
Avgoustiniatos ES, Mueller KR, Scott III WE, et al. Silicone rubber membrane devices permit islet culture at high density without adverse effects. Front Bioeng Biotechnol. 2024;12:1401608.
Building a similar workflow?
Talk to a ScaleReady specialist about how the G-Rex® platform can support your program — from process development to clinical-scale manufacturing.