Evaluated a closed-system manufacturing process for TCR-transduced T-cells. The rapid expansion phase utilized closed G-Rex® 500CS devices, yielding ~20 x 10^9 highly functional T-cells from a single vessel, improving safety and consistency.

What this paper found

A modular closed and semi-closed process produced clinical-scale HPV-16 E6 and E7 TCR-transduced T cells with high transduction efficiency and strong function. The 21-day process had a 7-day activation and retroviral transduction phase in culture bags, followed by a 14-day rapid expansion in a single closed gas-permeable G-Rex® vessel, and was tested on two healthy donors and four patients with epithelial cancers. Ten million transduced cells grown with allogeneic feeders yielded about 18.9 × 10^9 T cells, a 1890-fold expansion in the rapid phase, with transduction efficiencies of 64–92%. Effector memory cells dominated the product. E7 TCR cells killed 100 ± 1.9% of CASKi target cells at the 5-hour time point, and both TCR products secreted IFN-γ and TNF-α in a target-dependent manner.

Note: The evaluation used six donor samples in vitro; the authors note that a more naive T-cell phenotype is associated with greater long-term persistence, whereas this process yields mostly effector memory cells.

Large-scale manufacturing using modular systems and semi-automated devices resulted in highly functional clinical-grade TCR transduced T-cells. — Jianjian Jin, Nikolaos Gkitsas, Vicki S. Fellowes, Jiaqiang Ren, Steven A. Feldman, Christian S. Hinrichs, David F. Stroncek, Steven L. Highfill, Journal of Translational Medicine

Study details

Authors
Jianjian Jin, Nikolaos Gkitsas, Vicki S. Fellowes, Jiaqiang Ren, Steven A. Feldman, Christian S. Hinrichs, David F. Stroncek, Steven L. Highfill
Institution
Center for Cellular Engineering, Department of Transfusion Medicine, Clinical Center, National Institutes of Health, Bethesda, MD, USA · Experimental Transplantation and Immunology Branch, National Cancer Institute, NIH, Bethesda, MD, USA · Surgery Branch, National Cancer Institute, NIH, Bethesda, MD, USA
Journal
Journal of Translational Medicine
Year
2018
PMID / PMC
PMID: 29368612 · PMC
G-Rex® model(s)
G-Rex®500M-CS
Cell type(s)
TCR T Cells
Application area
Solid tumor
Study phase
Preclinical

How G-Rex® was used

Transduced T cells (10 × 10^6 viable cells) were seeded with 1 × 10^9 irradiated allogeneic feeder cells in a closed, gas-permeable G-Rex®500MCS vessel containing 800 mL of AIM-V-based medium with 3000 IU/mL IL-2, 5% human AB serum and 30 ng/mL anti-CD3. Medium was added on day 4 (800 mL, to 1600 mL), day 7 (1200 mL) and day 11 (1700 mL without serum, to 4500 mL). Cells were harvested on day 14, the supernatant removed with GatheRex, and the product concentrated and washed on a LOVO device. One vessel yielded approximately 18.9 × 10^9 T cells, a 1890-fold increase.