Tumor-infiltrating lymphocytes: Streamlining a complex manufacturing process

Overview
Reviews improvements to TIL manufacturing. Implementing G-Rex® 100MCS devices for the Rapid Expansion Protocol (REP) reduced technical interventions, media usage, and contamination risk while maintaining comparable tumor specificity to flask/bag methods.
What this paper found
Moffitt Cancer Center describes process changes that shorten and partly close the manufacturing of tumor-infiltrating lymphocytes for melanoma. Adding agonistic anti-4-1BB antibody to pre-REP tumor-fragment cultures increased the share of fragments with TIL outgrowth and the viable TIL yield. Moving the 14-day rapid expansion from T175 flasks and bags to G-Rex® 100MCS flasks gave 2310-fold expansion versus 729-fold, with 85% versus 74% viability at day 14. A phase 1 trial combining both changes shortened culture from 51 to 37 days and let all patients reach the 60 × 10^9 cell dose, versus 40% with traditional methods. Replacing polystyrene 24-well plates with gas-permeable G-Rex® plates for pre-REP gave comparable cell doses 7 days earlier. These changes enabled export of the process to multicenter trials.
Note: The REP comparison of G-Rex® 100MCS with flask-to-bag culture reports the mean of two independent experiments using TILs from different patients.
These process improvements were instrumental in facilitating export of the technology to other manufacturing sites to support multicenter clinical trials. — Emily L. Hopewell, Cheryl Cox, Shari Pilon-Thomas, Linda L. Kelley, Cytotherapy
Study details
- Authors
- Emily L. Hopewell, Cheryl Cox, Shari Pilon-Thomas, Linda L. Kelley
- Institution
- Cellular Therapy Core Facility, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA · Department of Immunology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA
- Journal
- Cytotherapy
- Year
- 2018
- G-Rex® model(s)
- G-Rex®100M-CS, G-Rex®24 Well Plate
- Cell type(s)
- TIL Cells
- Application area
- Solid tumor
- Study phase
- Preclinical
How G-Rex® was used
Moffitt replaced T175 flasks and gas-permeable bags in the 14-day rapid expansion with G-Rex® 100MCS flasks used together with the GatheRex Cell Harvest Pump for media replacement and harvest in a functionally closed system. In the comparison, 5 × 10^6 preREP TILs were cultured with IL-2 (3000 IU/mL), normal donor mononuclear cells and agonistic anti-CD3 (30 ng/mL) using minimal media exchange. By day 14, G-Rex® cultures held 1.16 × 10^10 cells (2310-fold) versus 3.7 × 10^9 (729-fold) in flask-to-bag cultures. In pre-REP, 24-well G-Rex® plates replaced polystyrene plates for tumor fragments, giving comparable cell doses 7 days earlier.